• True amperometric test method • Measures free or total chlorine residuals • Applications include fresh water, wastewater, and food processing • Simple to calibrate and operate • Uses inexpensive, non-toxic, food-grade vinegar for pH buffering • Continuous, isolated, 4-20 milliamp output signal, suitable for control or monitoring applications • Built-in high and low alarm relays • Field-adjustable range • High range capabilities to 100 ppm without dilution |
||
![]() |
The Foxcroft FX-1000p Chlorine Residual Analyzer utilizes the most accurate test method to determine chlorine residual levels in process waters, similar to that used in lab environment titrator test methods. This makes it an excellent choice for chlorine control or monitoring applications. Residual readings are instantaneous and do not rely on "sample and hold" methods. This minimizes any delay in readings for control applications. The continuous 4-20 milliamp output signal can be used to drive chlorine residual control systems and/or chart recorders, data loggers or SCADA systems. The alarm outputs can alert plant operators to an out-of-range chlorine residual, or trigger an autodialer in remote or off-hour situations. The measuring cell design incorporates several features to ensure accurate readings, such as; high-grade gold and copper electrodes, fixed sample and buffer feed rates, and continuous cell mixing and cleaning. Solid-state analog electronics provide stable, drift-free, residual readings and output signal. Electronic isolation eliminates problems from "gound-loop" and ensures operator safety. The analyzer is designed to be relatively maintenance-free, other than adding vinegar when it runs out. The use of vinegar as a pH buffer is simple, effective, economical, and environmentally friendly. Converting the analyzer to read total chlorine, is as simple as adding Potassium Iodide to the vinegar buffer. |
|
![]() |
Zero Chemical Discharge (does not pollute the environment) |
![]() |
![]() |
|
• True amperometric test method • Constantly measures free chlorine residuals • Applications: Drinking Water • Simple to calibrate and operate • Low maintenance design • Continuous, isolated, 4-20milliamp output signal, suitable for control or monitoring applications • Built-in high and low alarm relays • Field-adjustable range • High range capabilities to 100 ppm (mg/l) without dilution |
||
![]() |
The Foxcroft FX-1000p-B Bufferless Chlorine Analyzer utilizes the most accurate test method to determine chlorine residual levels in process waters, similar to that used in lab environment titrator test methods. This makes it an excellent choice for your chorine control or monitoring applications. Residual readings are instantaneous and do not rely on "sample and hold" methods. This minimizes any delay in readings for control applications. The continuous 4-20 milliamp output signal can be used to drive chlorine residual, or trigger an autodialer in remote or off-hour situations. The measuring cell design incorporates several features to ensure accurate readings. Features include; high-grade gold and copper electrodes, fixed sample rates and continuous cell mixing and cleaning. Solid-state analog electronics provide stable, drift free, residual readings and output signals. Electronic isolation eliminates problems from "ground-loop" and ensures operator safety. |
|
![]() |
Zero Chemical Discharge (does not pollute the environment) |
![]() |
|
• DPD Colorimeter |
|
![]() |
|
• Alarm indicators, safety interlock warn of problem pool conditions or feed equipment failure, prevents chemical addition when water chemistry is incorrect. • Low flow safety contacts to disable chemical feed if re circulation system fails. • Meter readouts for the highest accuracy available in a small controller |
|
![]() |
The Series 300 Controller automatically and continuously maintain pool water chemistry. It monitors water conditions and adds chemical only as needed to provide you with significant cost savings through reduced chemicals, labor and maintenance. Since it always maintains optimum chlorine levels, the Series 300 Controller keeps your water sparkling blue and within treatment standards recommended by local, U.S. public health agencies. |
![]() |
|
• Automatic Control of Chlorine and pH Levels • Chlorine Display in PPM, Computer Corrected for pH • Alarm for High/Low Chlorine and pH • Chlorine Feed Lockout for Incorrect pH |
|
![]() |
The Model 447 Swimming Pool Chemistry Controller provides continuous automatic control of chlorine and pH levels. Continuous control means virtually constant chlorine and pH levels. Typical pool water problems disappear. No more complaints of: • Eyeburn • Chlorine Odor • Algae • Scaling and Corrosion The built-in alarm circuit provides an added element of safety by warning of a potentially harmful water condition. In addition, chlorine feed is locked out if the pH ever reaches an incorrect level. Chemical feed timers provide warning for feeder failure, depletion of chemicals or incorrect feed rate. Continuous control also means greatly reduced operating costs. • Reduce costs (chemicals, labor, electricity) up to 50% • Increase filter runs • Free pool personnel for other duties • Provide unattended evening and weekend control The primary goal of pool chlorination is protection of human health. This can be done most efficiently with the continuous control provided by a Model 447, In general, the 447 provides a safer, healthier, and more efficient pool environment. |
Foxcroft Equipment and Service Company, Incorporated 2101 Creek Road - Glenmoore, PA 19343 - USA 1.800.874.0590 - 1.610.942.2888 - FAX 1.610.942.2769 Email: sales@foxcroft.com All Rights Reserved - All material contained in this Web Site is copyrighted - No material or ideas contained within this Web Site shall be used or copied without written consent from Foxcroft. ©2009 RWI3rd |